AHRI# 214610355
Capacity 24K
Indoor IDUMSAG11D-24HRFN1-MR0W
Outdoor ODUMOX430-24HFN1-MR0W
Power supply V-Ph-Hz 208/230V,1Ph,60Hz
Power supply Voltage range V 187-253
Cooling (Standard conditions)
Capacity (range) Btu/hr 24000(6200~24600)
Input W 2520(292~2900)
Current A 11.2(1.95~12.7)
EER2 Btu/hr/W 9.5
SEER2 Btu/hr/W 18.5
Heating (Standard conditions)
Capacity (range) Btu/hr 24000(6800~26800)
Input W 2350(437~2900)
Current A 10.25(2.88~12.7)
COP W/W 2.99
HSPF4 Btu/hr/W 8.6
HSPF5 Btu/hr/W 6.6
Moisture removal L/h 2.7
MINIMUM CIRCUIT AMPACITY (Indoor) A 3
MAX. FUSE (Indoor) A 15
Indoor air flow (Turbo/Hi/Mi/Lo) CFM 727.65/546.47/402.35/330.59
Indoor noise level (Hi/Mi/Lo) dB(A) 45/39.5/36
Indoor unit
Dimension (W*D*H) mm 1082x234x337
Dimension (W*D*H) inch 42.60×9.21×13.27
Packing (W*D*H) mm 1155x415x315
Packing (W*D*H) inch 45.47×16.34×12.40
Net/Gross weight kg 13.6/17.3
Net/Gross weight lb 29.98/38.14
MINIMUM CIRCUIT AMPACITY (Outdoor) A 19
MAX. FUSE (Outdoor) A 30
Outdoor air flow CFM 1764.71
Outdoor noise level dB(A) 60
Throttle type Throttle valve
Outdoor unit
Dimension (W*D*H) mm 890x342x673
Dimension (W*D*H) inch 35.04×13.46×26.50
Packing (W*D*H) mm 995x398x740
Packing (W*D*H) inch 39.17×15.67×29.13
Net/Gross weight kg 44.4/47.4
Net/Gross weight lb 97.88/104.50
Refrigerant type R410A
Connection wiring 14#x4
Thermostat type Remote Control







Reviews